Beamline Critical Devices

M:HV100

Control Device : D:M1CDC

Areas Protected : Muon Campus Pre-Vault, Vault, Transport

Test Procedure

1. Call up digital status for D:M1CDC.

2. Turn on M:HV100 via a parameter page.

3. Verify the digital status for D:M1CDC indicates the power supply is ready and on.

4. Issue an off command from the digital status page to the critical device controller.

5. Verify the digital status for D:M1CDC indicates the power supply is off.

6. Document the results in the MCR Logbook.