Beamline Critical Devices

D:BS707

Control Device : D:DELCDC

Areas Protected : Muon Campus Delivery Ring, Extraction Enclosure

Test Procedure

1. Call up digital status for D:DELCDC.

2. Open the beam stop by issuing an on command via the digital status page to the critical device controller.

3. Verify the digital status for D:DELCDC indicates the beam stop is open.

4. Issue an off command from the digital status page to the critical device controller.

5. Verify the digital status for D:DELCDC indicates the beam stop is closed.

6. Document the results in the MCR Logbook.